Filters
Absolutely No Tariff Charges! FIELD COMPONENTS INC. Achieves AS9100D Quality Management Certification

Secure Checkout

Absolutely No Tariff Charges! FIELD COMPONENTS INC. Achieves AS9100D Quality Management Certification
Your Shopping Cart Is Empty

Secure Checkout

RG188 Cable Assemblies

Sort Products By
RG188  Cable Assemblies

RG188 A/U Specifications

# Coax AWG Stranding Conductor Material Dia. (in.)
1 26 7x34 SPCCS - Silver Plated Copper Covered Steel .0205

 


Insulation Material:

Insulation Trade Name Insulation Material Dia. (in.)
Teflon(R) TFE - Tetrafluoroethylene .058

Outer ShieldOuter Shield Material:
Type Outer Shield Material Coverage (%)
Braid SPC - Silver Plated Copper 96

Outer JacketOuter Jacket Material:
Outer Jacket Trade Name Outer Jacket Material
Teflon(R) TFE - Tetrafluoroethylene

Overall Cable
Overall Nominal Diameter: 0.098 in.
Mechanical Characteristics (Overall)
Operating Temperature Range: -70C To +200C
UL Temperature Rating: 200C
Bulk Cable Weight: 10 lbs/1000 ft.
Max. Recommended Pulling Tension: 21 lbs.
Min. Bend Radius (Install)/Minor Axis: 1.500 in.


Applicable Specifications and Agency Compliance

(Overall)Applicable Standards & Environmental Programs

EU CE Mark: No
EU Directive 2000/53/EC (ELV): Yes
EU Directive 2002/95/EC (RoHS): Yes
EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005
EU Directive 2002/96/EC (WEEE): Yes
EU Directive 2003/11/EC (BFR): Yes
CA Prop 65 (CJ for Wire & Cable): Yes
MII Order #39 (China RoHS): Yes
Military Specification: MIL-C-17D
RG Type: 188A/U


Flame Test

UL Flame Test: UL1685 UL Loading, VW-1

Plenum/Non-Plenum
Plenum (Y/N): No

Electrical Characteristics (Overall)Nom. Characteristic Impedance:
Impedance (Ohm)
50

Nom. Inductance:
Inductance (µH/ft)
0.067

Nom. Capacitance Conductor to Shield:
Capacitance (pF/ft)
29.0

Nominal Velocity of Propagation:
VP (%)
69.5

Nominal Delay:
Delay (ns/ft)
1.47

Nom. Conductor DC Resistance:
DCR @ 20C (Ohm/1000 ft)
91.2

Nominal Outer Shield DC Resistance:
DCR @ 20C (Ohm/1000 ft)
8.5

Nom. Attenuation:
Freq. (MHz) Attenuation (dB/100 ft.)
1 1.2
10 2.7
50 5.6
100 8.3
200 12.0
400 17.5
700 23.7
900 27.3
1000 29.0

Max. Operating Voltage - Non-UL:
Voltage
900 V RMS
Connector side 1
Connector side 2

Cable Type

Select Cable parameters